Repository LOGO
    • Login
    View Item 
    •   Intellectual Repository at Rajamangala University of Technology Phra Nakhon
    • Faculty and Institute (คณะและสถาบัน)
    • Faculty of Engineering
    • Research Report
    • View Item
    •   Intellectual Repository at Rajamangala University of Technology Phra Nakhon
    • Faculty and Institute (คณะและสถาบัน)
    • Faculty of Engineering
    • Research Report
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    The reduce effect of lightning on transmission line

    Thumbnail
    View/Open
    ENG_61_43.pdf (17.63Mb)
    Date
    2018-09-22
    Author
    Rugthaicharoencheep, Nattachote
    Chalangsut, Aroon
    นัฐโชติ รักไทยเจริญชีพ
    อรุณ ชลังสุทธิ์
    Metadata
    Show full item record
    Abstract
    Most of Metropolitan Electricity Authority (MEA) electric power system is using overhead line. It is 94% in the system including subtransmission, distribution and low voltage system. All of them were installed on concrete pole. At present, many public facilities have been built such as Sky-Train. It causes more constrains for construction with concrete pole due to lack of right of way. MEA needs to using electrical monopole plays an important role. It’s easier than concrete pole for construction and it requires less construction area than concrete pole. This research evaluation of The Reduce Effect of Lightning on Transmission Line. Case lightning strike on overhead ground wire (OHGW) at pole top of electrical monopole with suspension insulator, Focusing on three factors is pole top voltage, critical current and back flashover rate (BFOR). ATP-EMTP software is used for simulation. The results show that BFOR is reduced by 79% on electrical monopole structure with suspension insulator compared with existing concrete pole. BFOR is also reduced by 33.17% on concrete pole with external ground wire. The results could be served as a guideline in subtransmission line design and improvement in MEA power system.