Repository LOGO
    • Login
    View Item 
    •   Intellectual Repository at Rajamangala University of Technology Phra Nakhon
    • Faculty and Institute (คณะและสถาบัน)
    • Institute of Research and Development
    • Journal Articles
    • View Item
    •   Intellectual Repository at Rajamangala University of Technology Phra Nakhon
    • Faculty and Institute (คณะและสถาบัน)
    • Institute of Research and Development
    • Journal Articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Load frequency control of solar farm and wind turbine for interconnected power system

    Thumbnail
    View/Open
    IRD_62_38.pdf (321.5Kb)
    Date
    2020-01-07
    Author
    Yukhalang, Sawat
    สวัสดิ์ ยุคะลัง
    Metadata
    Show full item record
    Abstract
    The effects of load frequency control (LFC) of interconnected distribution power system in tie-line substation area, load –frequency stability and the frequency respond at distribution generator (DG) are very important for interconnected control power system of tie-line area. The generating power system of solar farm and wind turbine which have interconnected distribution power system in tie-line substation area were tested using 3 simulation parameters: non-controller, Automatic Voltage Regulator (AVR) and with Pl Controller. The results showed that there were 3 types of load and frequency changing in the interconnected area: load changed 0.02 p.u. had frequency of load changed 0.025 Hz and large disturbance. Comparisons of load-frequency to respond for steady state, the time respond was 7.9 seconds for non-controller, 5.4 seconds for AVR and 1.7 seconds for under controlled system at 0.1 p.u using Pl controller. Therefore, the Pl controller has better efficiency than non-controller about 31 % and AVR about 16%. It can be concluded that the interconnected distribution power system in tie-line substation area controlling for storage for connected grid had better efficiency and optimization of generating power from renewable solar farm and wind turbine which have interconnected distribution power system in the nearby are balance of controlling of the original system.
    URI
    http://repository.rmutp.ac.th/handle/123456789/2877
    Collections
    • Journal Articles [688]

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     


    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV