    Reactive power control to improve the economic of power system

    Thumbnail
    View/Open
    ENG_62_07.pdf (3.300Mb)
    Date
    2020-02-18
    Author
    Rugthaicharoencheep, Nattachote
    นัฐโชติ รักไทยเจริญชีพ
    Chalangsut, Aroon
    อรุณ ชลังสุทธิ์
    Metadata
    Show full item record
    Abstract
    To Improvement the power factor is very important. Because the costs are increased or reduced. To Improvement the power factor, the higher the value, it is necessary to buildings, offices and industrial buildings or the fact that the industry needs real power. And reactive power source to operate. This research presents the design and construction of reactive power factor control. Which amounted to 6 working order by the first sequence is divided into three three-phase electrical power system and three consecutive singles phase by active power different. first1 is reactive at 5 kVAr second 2 and third 3 are reactive at 2.5 kVAr forth 4, fifth 5 and sixth 6, precious marine active 0.83 kVAr control. the power factor controller that controls RG3-12 pay Oval active in various sequences. As a result, when not equipped with reactive power compensation software to control the power factor. This makes the flow of the high and low Power Factor schedule. When equipped compensate reactive power source to power factor control. Single-phase motor 1 kW and light bulb 1,640-watt making the current decline of 14 amps rest 12 amps of the power factor increases from 0.5 to 0.929. When connected to three-phase motor with 2 kW 0.8, 2.2 flow down from 2.360 rests 0.942 amps of power factor value up from 0.308 to 1.0.
    URI
    http://repository.rmutp.ac.th/handle/123456789/3156
    Collections
    • Research Report [286]

    Related items

    Showing items related by title, author, creator and subject.

    • Power quality analysis of solar power plant 1 mw and impacts an economic value in distribution power networks 

      Charlangsut, Narate; นเรศ ชลังสุทธิ์ (2017-10-31)
      This thesis presents the Power Quality (PQ) analysis of solar power plant 1MW and economic impacts in the distribution power networks. The case study focuses on the penalty fee (fine) from consume the reactive power less ...
    • A comparative power transmission between air core trans-former and lron core transformer of class-e power amplifier 

      Mansattha, Muhammad; มุหัมมัด มั่นศรัทธา; Ruangkarn, Rachata; รชต เรืองกาญจน์ (2020-09-07)
      This paper presents the simulation and experimental result of class-E power amplifier. It is often used in designing a high frequency ac power source because its ability to perform the conversion efficiently even at high ...
    • Simulation of a 500 kW sloped solar chimney power plant powered by industrial waste heat 

      Chansawang, Bandit; บัณฑิต จันทร์สว่าง; Koonsrisuk, Atit; อาทิตย์ คูณศรีสุข (2020-09-21)
      The solar chimney power plant (SCPP) has been proposed as a promising alternative power plant. According to the literature, the chimney for commercial-scale SCPPs should be about 1 km high. The construction of these tall ...