Repository LOGO
    • Login
    View Item 
    •   Intellectual Repository at Rajamangala University of Technology Phra Nakhon
    • Faculty and Institute (คณะและสถาบัน)
    • Faculty of Engineering
    • Independent Study
    • View Item
    •   Intellectual Repository at Rajamangala University of Technology Phra Nakhon
    • Faculty and Institute (คณะและสถาบัน)
    • Faculty of Engineering
    • Independent Study
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    A study of the appropriate factor level for improving annealing process of rolled coil steel sheet

    Thumbnail
    View/Open
    ENG_64_10.pdf (12.14Mb)
    Date
    2021-02-25
    Author
    Chueaduangkhao, Sittipong
    สิทธิพงษ์ เชื้อดวงขาว
    Metadata
    Show full item record
    Abstract
    The objective of this research is to study the suitable factor level for the improvement of annealing furnace for rolled coils steel sheet. The experimenting has been performed to find suitable oxygen level by 5 annealing furnace experiment. The research has been started by collection the combustion. After that the burning adjustment by changing combustion technology with 5 levels of BGCV control valve open as 23%, 40%, 50%, 75% and 100% has been implemented. The combustion adjustment data are recorded, analyzed and compared with incomplete combustion value. The research result has been found that after improvement the combustion value. The percentage of oxygen level are improved to the better quality which standard at MV0-49% equal 2.5-4 O2% and MV50-100% equal 1.5-2.5 O2% conclusion 1 furnace as follows at the MV23.1%, MV40%, MV50%, MV75% and MV100% level of oxygen as 2.5%, 3%, 3%, 2%, 1.5% and level of carbon monoxide as 0 ppm, 2 ppm, 2 ppm, 2 ppm, and 0 ppm respectively. Resulting of fuel energy consumption in the annealing process has been reduced around 225,608 baht /year/furnace. Therefore, it can depict that energy saving and annealing furnace efficiency improving are increased. The modified parameters will be applied to be the new standard reference values for the further engineer’s operational manual.
    URI
    http://repository.rmutp.ac.th/handle/123456789/3579
    Collections
    • Independent Study [31]

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     


    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV