    Strengthening of deteriorated reinforced concrete deep beam caused by chloride with carbon fiber sheets

    Thumbnail
    View/Open
    IRD_64_10.pdf (2.987Mb)
    Date
    2021-08-07
    Author
    Hongthong, Rattanasak
    รัตนศักดิ์ หงษ์ทอง
    Benjaphong, Apai
    อภัย เบ็ญจพงศ์
    Jairtalawanich, Thamma
    ธรรมมา เจียรธราวานิช
    Metadata
    Show full item record
    Abstract
    Deterioration of reinforced concrete deep beam structure caused by chloride is severe andtakes up wide area even though the structure is not exposed to sea water or brackish water. Even the structure which is far from sea water or brackish water is affected by this problem.When the reinforced concreate deep beam structure is affected by chloride, steel reinforced inside the structure is corroded resulting in reducing the cross-sectional area of the reinforced steel affecting load capacity, deflection and beam failure. If there is no repair or strengthening, such capabilities are continuously reduced until it is no longer safe to use the beam. Therefore, it is necessary to repair or strengthening the deteriorated structure to be safely used. This research investigated strengthening of deteriorated reinforced concrete deep beam caused by chloride with 4 formats of carbon Fiber sheets to seek guidelines for the most efficient strengthening. The resultshowed that the strengthening by the 4 format of carbon fiber sheet could increase ultimate loadcapability yet could not improve ductility of the deteriorated beam to become close to the beamthat is not deteriorated. The strengthening that could increase the maximum ultimate load capability was the table format strengthening. In addition, the strengthening that the carbon fiber making 45 degrees with the length of the beam could best prevent diagonal cracks.
    URI
    http://repository.rmutp.ac.th/handle/123456789/3609