Repository LOGO
    • Login
    View Item 
    •   Intellectual Repository at Rajamangala University of Technology Phra Nakhon
    • Faculty and Institute (คณะและสถาบัน)
    • Faculty of Engineering
    • Theses
    • View Item
    •   Intellectual Repository at Rajamangala University of Technology Phra Nakhon
    • Faculty and Institute (คณะและสถาบัน)
    • Faculty of Engineering
    • Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Suitability study of using air conditioning system in office building for energy conservation and thermal comfort conditions

    Thumbnail
    View/Open
    ENG_65_01.pdf (46.20Mb)
    Date
    2021-11-03
    Author
    Mekkhum, Pattana
    พัฒนะ เมฆขำ
    Metadata
    Show full item record
    Abstract
    Presently, Rental office is famous in downtown that near food center and have good transportation. In Thailand, office buildings usually have operating time 8-10 hours per day. So, need to improve the building for energy conservation and employee’s comfort. Glasses are one way that heat transfers occur highly. Overall Thermal Transfer Value (OTTV) is a tool for measure heat transfers through building envelope. From OTTV calculation for existing building, OTTV is 92.94 W/m2 that over ministerial regulations indicate 50 W/m2. Improving building envelope by add more thickness of glasses can reduce OTTV 1.3% and improving building envelope by film installation can reduce OTTV 47.2% and improving building envelope by add shading can reduce OTTV 48.5%. However, each improving policy have each investment cost. Conjoint analysis is consider of many factor to find willingness to pay for each choice. So, set policies for energy conservation, water and waste management and increase comfort are employees to improve energy conservation, water and waste management and increase comfort are 19,935.90, 17,590.50 and 1,563.60 baht respectively, so can improve building envelope by add shading result in OTTV to 47.8 W/m2, Budget 18,000 Baht can be improve organization that payback about 5,400 Baht per year. Increase thermal comfort by install table fan. From the result of research expect to apply to improve rental office in the future.
    URI
    http://repository.rmutp.ac.th/handle/123456789/3733
    Collections
    • Theses [42]

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     


    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV